In short
About a sixteen-minute read · Updated- What it measures
- How loud, in dBA, every minute. And what kind of sound.
- Office
- Under 45 dBA. PitCanary's band for an office. Above it, talking carries.
- Hotel room
- Under 30 dBA at night. PitCanary's band for a hotel room, and the WHO's 1999 figure for a bedroom at night.
- What hurts work
- Talking you can follow. Not the decibel level itself.
- Reverberation
- How long a sound hangs in the room. The longer it rings, the louder the room.
- Hearing damage
- EU action values: 80 and 85 dBA over eight hours. Few offices come near either.
- PitCanary
- Tells quiet, conversation and music from other sounds. No audio.
- Your data
- Every reading is yours. Download it or use the API, free.
Fifty people, one floor, a pool table and an iPad.
One of the offices I worked in had almost fifty people on one open floor. No separate rooms, one big space. Somebody put speakers in, and anyone could change the music from their own computer, so it was turned up all day. The music got its own iPad, so you had to walk over to change it. It still ended up too loud for most people. There was a pool table too, loud and low, and the people next to it nearly caught a ball in the neck. People bought noise-cancelling headphones just to get through the afternoon.
Then came a decibel meter. A big one, with a row of LEDs, so everyone could see how loud the floor was. Over the limit it blinked. Later came lamps that turned green: green meant quiet, no talking, so people got blocks in the day to concentrate. It helped. It also made it the office with a blinking noise meter and traffic-light lamps.
A PitCanary would have shown it in the first week: which hours were talking, which were music, when the loud stretches came, and how little of the day was quiet long enough to think. The lamps were not wrong. There was just nothing that said when to switch them on.
What is office acoustics?
Office acoustics is how a workplace handles sound: how loud it is, how long sound rings in the room, and how far speech carries, which together decide whether people can concentrate. The level in decibels is the smaller half of the story. A busy street outside the window is easier to work next to than one conversation two desks away, even when the street is louder. The street is a hum. The conversation has words, and the brain follows words whether you want it to or not.
That is why open offices feel worse than their decibel readings. The level is fine on paper. What fills it is speech, from everywhere, all day. Research on this is old and consistent: talking you can understand lowers performance on memory and reading work more than noise without words. Headphones are the visible symptom. When half the floor wears them, the room has failed.
The room itself matters too. A room with hard floors, glass walls and a bare ceiling keeps every sound alive for a long time, so people talk louder to be heard over the people talking louder. That is reverberation, and it is why the same twenty people are fine in one room and unbearable in another.
What you notice
- Headphones on
- Not for music. For silence. The sign that the room is too loud to think in.
- Tired by three
- Filtering out voices all day costs energy. People leave an open office more tired than a busy one.
- Reading the same line twice
- Talking nearby breaks reading and memory first. Routine work holds up longer.
- Everyone talks louder
- In a hard, echoey room, voices climb to be heard over each other. The room sounds louder than the people in it.
You feel the afternoon was loud. PitCanary can show it was conversation from one to five, music from four, and how long the longest quiet stretch lasted.
Sources: Banbury and Berry, 2005; Hongisto, 2005; Jahncke et al., 2011.
How many decibels is too loud for an office?
For focused work an office is too loud above about 45 dBA of background sound, the top of PitCanary's office band, because above it talking carries across the room. For hearing the limits are far higher: the EU sets two action values, 80 and 85 dBA over an eight-hour day, in Directive 2003/10/EC, and few offices come near either.
Decibels are a strange scale. Ten more sounds twice as loud. Three more is twice the sound energy. Two people talking are three decibels louder than one, not twice as loud. So the number on a decibel meter means little to most people: 44, 52, 61, and none of them tells you whether anyone can work.
PitCanary cuts the scale into three bands, set for the room type, and the device breathes the colour. Green is the lamp we used to switch on by hand. It also knows the difference between a loud room and a hollow one, and between talking and an appliance, which a decibel meter does not.
Quiet. Good for focused work.
Busy. Talking carries across the room.
Loud. Nobody is concentrating.
Room bands from PitCanary's room type registry, and the WHO Guidelines for Community Noise (1999) for a bedroom at night. Hearing protection limits from EU Directive 2003/10/EC. Each market reads the bands against its own standard; the colours stay, the edges move.
What does noise monitoring show over a day?
Noise monitoring shows how loud a room was every minute, and with PitCanary also what kind of sound filled it, which a daily average hides. Take one Tuesday in an open office. Overnight the room is quiet, around 30 dBA, the hum of the building. From seven people arrive and the level climbs. The middle of the day is other sound: activity, doors and equipment, up to 61 dBA at one. From three the conversation takes over and keeps going into the evening, with two short bursts of music. The loudest moment of the day, about 80 dBA, is around half past nine in the evening.
The same example day in words. The room was quiet for about 8.5 hours, 5 of them between 22:00 and 07:00. Conversation took about 2.3 hours, mostly from 13:00 into the evening. Other sound, such as activity, doors and equipment, took about 3.5 hours, most of it from 11:00 to 14:00. Music played for about 0.1 hours, in two short bursts around midday and in the evening. The level averaged 49 dBA, from 29 dBA overnight to 61 dBA at one, with the loudest hour at about 80 dBA around half past nine in the evening.
A decibel meter would have said 49 on average. A good day, on paper. The scene mix says the room was quiet for about eight and a half hours, and most of them were at night.
Is the noise from the people or the building?
The pitch of the sound tells the people from the building: ventilation hums low and steady, speech sits in the middle, and the dashboard draws a day of both as one landscape. Loudness is one number. Sound has many. The floor of the landscape is the day, the depth is the pitch from a low rumble at the front to a high hiss at the back, and the height is how loud each pitch was. The ventilation shows as a flat ridge at the low end that never moves. Talking shows as hills in the middle, in working hours. Music with a heavy bass shows as a hill at the front. One look tells you what fills this room, and whether it is the people or the building.
A decibel meter does not draw this. PitCanary builds it from the band levels it sends every minute, and not one of them is a recording.
What is reverberation time?
Reverberation time, RT60, is the number of seconds a sound takes to fade by 60 dB after it stops, and it decides how loud the same people sound in a room. Clap in an empty office with a tiled floor and the clap hangs in the air for a second. Clap in a carpeted room with an acoustic ceiling and it is gone. Hard room, loud room.
The estimate needs sounds with a clear tail, so it fills in over days, not minutes.
The sum is simple and a hundred years old: the reverberation time grows with the volume of the room and falls with the surfaces that absorb sound. Glass, concrete and plaster absorb almost nothing. Carpet, curtains, acoustic ceilings and people absorb a lot.
How echoey is your room?
- Reverberation
- 1.93secondsEchoey
- Volume
- 81m³
- Absorption
- 7m²
Acoustic ceiling tiles would bring it to 0.44 s, inside the band.
An estimate from the Sabine formula, RT60 = 0.161 × V / A, and typical absorption values at 1 kHz. Its band, 0.4 to 0.8 s, is drawn to orient you, not taken from a standard. A PitCanary in the room estimates it from the room's own sounds.
How do you improve office acoustics?
Improve office acoustics by taking the hardness out of the room, moving the talking somewhere else, and giving people hours that are quiet by agreement. Measure for a month before and after, so you know which change worked. For the quiet blocks, the PitCanary's own Focus and Pomodoro mode turns its light steady red while a block runs and green on a break.
-
Soften the surfacesAcoustic ceiling tiles, carpet, curtains, panels on the glass. Each one shortens the reverberation time, and a quieter room makes people talk more quietly.
-
Put the talking somewhere elsePhone booths and a room for calls take the one sound that breaks concentration off the floor.
-
Agree quiet blocksTwo hours a day with no talking on the floor, and the timeline shows whether they held.
-
Move the noise, not the peopleThe printer, the coffee machine and the pool table each get their own room or corner. The scene mix shows what they cost.
If a room is always orange whatever you do, it is too hard or too full for the work done in it. That is a finding, not a failure, and a month of scene mix is what makes the case for panels, booths or a wall.
What does a decibel meter measure, and what does it miss?
A decibel meter, or sound level meter, measures how loud the air is at the microphone, in decibels weighted to the ear (dBA), at one moment. A good one is calibrated. A phone app is not: a phone's microphone is built for calls, not for measuring. For a one-off check, or to settle an argument about the music, a meter does the job.
What it does not know is what the sound was. 55 dBA is a conversation at the next desk or a ventilation unit; one breaks concentration, the other does not. It does not know how long the quiet stretches were, which is what focus needs. And it does not know how the room handles sound, which decides whether the same people are fine or unbearable.
PitCanary reads the level the same way, every minute, and adds the three things the meter misses: what kind of sound, how long the quiet lasted, and how the room rings. It is a room monitor, not a calibrated class 1 or class 2 sound level meter. For a legal or contractual measurement, use one.
How does PitCanary monitor noise without recording?
PitCanary classifies the sound on the device itself and sends only a label and a handful of numbers, so no audio is ever recorded, stored or sent. Every minute it decides what kind of sound the room had: quiet, conversation or music, or one of a few others such as typing, a phone ringing, a door or a vacuum cleaner. What leaves the device is the label, the level, the strength across frequency bands, and the shape of the sound, such as how much it has the rhythm of speech or the beat of music. From those the dashboard knows that the floor was talking from one to five, not what was said.
- It is about the room, never a person.
The device cannot tell who spoke, only that speech was in the room.
- Nothing leaves the tile but labels and numbers.
No audio is recorded, stored or sent. The numbers it does send are in the API and on the dashboard, so you can see exactly what it knows.
- You can switch it off.
Sound classification is a setting. Off means the device only reads the level, like any decibel meter.
Read together, the afternoon explains itself. The level was flat at 50. The speech line says it was talking until five and music after, and the room was in use the whole time.
- Level
- dBA every minute, with the quietest and loudest minute of each hour.
- Scene
- Quiet, conversation, music and a few other sounds, classified on the device. No audio.
- Room
- An estimate of the reverberation time, and the sound landscape, from band levels every minute.
- Exposure
- The day's sound exposure, read against the EU workplace noise rules, for the room, never for a person.
Can you log noise levels over time?
Yes: PitCanary keeps every sound reading of every minute as numbers, where most decibel meters show the number now and forget it a minute later. Every reading, level, scene and room, goes into a log for the room, with the temperature, air quality and light next to it. Months later you can still see which afternoons went to talking, for how long and why.
That log is yours, not ours. Getting it out costs nothing: no export fee, no paid tier for your own history.
| Time | Sound dBA | Scene | Quiet stretch | Occupancy |
|---|---|---|---|---|
| 14:31 | 52 | Conversation | 0 min | Present |
| 14:32 | 54 | Conversation | 0 min | Present |
| 14:33 | 49 | Other sound | 0 min | Present |
- On the timelineEvery hour of every day, with what changed and why.
- As a downloadBy room, day or month, as CSV.
- Through the APIInto your building system, BI tool or app.
So you read a day the way you read a log. Not a number at this minute, but what changed and why.
- 15:10: voices for 40 minutes. Conversation, on and off, from 14:30 to 15:10, with the room busy. Forty minutes that were hard to focus in.
What noise level should each room have?
Each room type has its own background level: under 45 dBA for an office in PitCanary's bands, and under 30 dBA in a bedroom at night under the WHO Guidelines for Community Noise (1999). A meeting room, an open floor and a hotel room at night all want different things, and two of them care more about the reverberation than the level. This table is the reference: the room, the background level it should stay under, the reverberation it should have, and what to watch.
| Room | Background level | Reverberation | What to watch | Source |
|---|---|---|---|---|
| Open office | Under 45 dBA | As short as practical | Talking that carries more than a few desks | PitCanary's band |
| Private office | Under 45 dBA | Short | Outside noise through the window | PitCanary's band |
| Meeting room | Under 45 dBA | Short | Hollow rooms make calls unintelligible | PitCanary's band |
| Reception | Under 45 dBA | Short | Voices from the waiting area reaching the desk | PitCanary's band |
| Hotel room | Under 35 dBA, under 30 dBA at night | – | Corridor doors, lifts and the room next door | 30 dB inside the bedroom during sleep (WHO Guidelines for Community Noise, 1999) |
| Bedroom at night | Under 30 dBA | – | Traffic and neighbours | 30 dB inside the bedroom during sleep (WHO Guidelines for Community Noise, 1999) |
| Restaurant | Under 65 dBA | Short | A full room that makes everyone talk louder | For the staff, 80 and 85 dBA over eight hours (Directive 2003/10/EC) |
The band column is the one PitCanary reads that room type against, from its room type registry. Sources for the guidance column: WHO Guidelines for Community Noise, 1999 (hotel rooms and bedrooms at night); EU Directive 2003/10/EC (the staff of a restaurant). The other rows are PitCanary's bands. The reverberation column gives the direction to aim for; the calculator above estimates a room's own.
PitCanary knows fifteen room types and reads each against its own band. Set the room type once. The light, the timeline and the Room score do the rest. Sound is one of five parts of a good indoor climate, and a floor that shakes is the next question on the vibration monitoring page.
Questions about office acoustics and noise monitoring
What is office acoustics?
How a workplace handles sound: how loud it is, how long sound rings in the room, and how far speech carries. Together they decide whether people can concentrate. Speech you can follow costs more concentration than a louder hum without words.
How many decibels is a normal office?
PitCanary reads an office against under 45 dBA, its own band, and a hotel room against under 35, under 30 at night. On an open floor, talking carries across the room and focus drops.
How many decibels is too loud for work?
For hearing, the EU sets two action values over eight hours, a lower one at 80 dBA and an upper one at 85 (Directive 2003/10/EC). For thinking, far lower: it is not the level but speech you can follow. One conversation nearby costs more concentration than a louder street outside.
What is a decibel meter?
A sound level meter: a microphone that reads how loud the air is, in dBA. A good one is calibrated; a phone app is not, so its reading can be far off. It reads the level, not what the sound was. PitCanary reads the level every minute and tells quiet from conversation, music and a few other sounds.
What is noise monitoring?
Logging the sound level of a room continuously, so you see when it was loud and for how long instead of one reading. A noise monitor such as PitCanary also keeps the quietest and loudest minute of each hour and labels what kind of sound it was, without recording audio.
What is reverberation time?
How long sound hangs in a room after it stops, in seconds. The shorter it is, the clearer voices sound. Hard floors, glass and bare ceilings make it long, and the room sounds loud and hollow. Carpet, panels and acoustic ceilings bring it down.
How do I improve office acoustics?
Soften the surfaces first: acoustic ceiling, carpet, panels on glass. Then move the talking: booths for calls, a room for meetings. Then agree quiet hours. Measure for a month and see what changed.
Does PitCanary record conversations?
No. The device classifies sound on the tile: quiet, conversations, music and a few other sounds. No audio is stored or sent. Only the label and a handful of numbers leave the device, they are visible in the API and the dashboard, it is always about the room and never a person, and you can switch the classification off.
How do you reduce noise in an open plan office?
Move the talking out of the open floor first: phone booths for calls and a room for meetings. Then soften the surfaces with an acoustic ceiling, carpet and panels, and agree quiet hours. A noise log per room shows which hours were loud and whether the change helped.