In short
About a fifteen-minute read · Updated- What it measures
- Air that was already breathed. More people, more CO₂.
- Outdoor air
- About 420 ppm. A room never gets below it.
- The standard's office line
- About 1,220 ppm. That is 800 ppm above outdoor, EN 16798-1.
- PitCanary's band, office
- Under 1,000 ppm. The German ASR A3.6 line, stricter than EN 16798-1.
- A CO₂ monitor
- Shows the CO₂ now. A CO₂ data logger also keeps the whole day.
- When it is too high
- Open the windows wide for five to ten minutes.
- PitCanary
- Logs CO₂ every minute next to 14 other measurements, and shows the room as a colour on the device.
- Your data
- Every reading is yours. Download it or use the API, free.
Why measure CO₂ in an office? Because the afternoon dip is often the air.
After lunch, the CO₂ meter in office after office read over 1,200 ppm, right at the standard's office line. I have worked in offices for almost twenty years, in old buildings and new ones, on open floors and in small meeting rooms. In nearly all of them the afternoon went the same way: heavy eyes, slow heads, an hour that never got going. I blamed lunch.
Then I started measuring. The CO₂ was high even with the windows open, because windows in one corner let air in but did not move it through. The air was costing the best part of the working day and nobody knew.
A PitCanary shows it in the first week. The same stretch turns orange on the timeline every afternoon, and the history proves it is the room, not the people.
What do CO₂ levels measure?
CO₂ levels measure how much of the air in a room has already been breathed, counted in parts per million (ppm). Every breath out holds far more carbon dioxide than the air you breathed in. In a room with people and too little fresh air, that CO₂ builds up. Outdoor air is about 420 ppm, and a little higher next to a busy road. No room ever gets below outdoor air, so what counts is what the people add on top.
CO₂ itself does little harm at the levels a room reaches. The EU workplace exposure limit is 5,000 ppm over eight hours, far above a normal room. What the number tells you is how much of the air has been through someone else's lungs first. You cannot see used air, but you can count it. That makes CO₂ the simplest measure of indoor air quality there is.
What high CO₂ levels feel like
- Sleepiness
- From about 1,000 ppm. The most common complaint. In tests, people got drowsy sooner as CO₂ rose, more so after a bad night.
- Slower thinking
- Reported from about 1,000 ppm, not in every study. Some tests found decisions and planning suffered. Others, with CO₂ alone, found no effect: the stale air around it is the likelier cause.
- Headache
- No firm threshold. Dull, late in the day, gone after you leave. It comes with stale air, not with one figure.
- Heavy air
- From about 1,000 ppm. The room feels stuffy, mostly to whoever walks in from outside.
Nobody walks into a room and thinks: 1,400 ppm. They think the meeting is dragging. PitCanary measures it for them and shows the state of the room as a colour on the device.
Sources: outdoor CO₂ from NOAA; workplace limit from EU Directive 2006/15/EC; Snow et al., 2019; Satish et al., 2012; Zhang et al., 2017; ASHRAE 62.1; Rudnick and Milton, 2003.
What CO₂ level is too high in an office?
In an office, CO₂ above about 1,220 ppm is too high: that is the line of EN 16798-1 Category II, 800 ppm above outdoor air at about 420 ppm. Germany's workplace rule ASR A3.6 draws a stricter line at 1,000 ppm, and PitCanary uses that line for offices and meeting rooms. Above about 1,770 ppm a room is past Category III, and the air has been stale for a while.
A number in ppm means little to most people. 612, 1,140, 1,600: none of them tells you whether to open a window. So the standard cuts the scale into three bands, and the scale below reads them as three colours.
The base of the PitCanary breathes green, orange or red for the Room score, and CO₂ is part of its Air share. Everyone in the room sees the state of the air at a glance, with no app and no screen. Orange is not an alarm. It is a nudge, early enough that one open window is enough.
Fresh. The air is refreshed as fast as people use it.
Stale. Open a window or turn up the ventilation.
Ventilate now.
These are the bands of the European standard EN 16798-1, read against outdoor air at about 420 ppm. Category II, the normal level for offices and hotel rooms, is 800 ppm above outdoor: about 1,220 ppm. Category III is 1,350 above outdoor: about 1,770 ppm. Other markets use their own rule, such as ASR A3.6 in Germany, so the colours stay and the edges move.
PitCanary judges each room against its own band for the room type, which can be stricter than the standard. That is 1,000 ppm for an office, 1,200 for a gym and 800 for a bedroom. The scale above is the standard's, so you can read any room against it.
What do normal CO₂ levels indoors look like over a day?
Normal CO₂ levels indoors run from about 420 ppm in an empty room at night to 1,000 ppm or more during a full meeting. This is one Tuesday in a meeting room for eight. Overnight the air settles back to outdoor level. People arrive from half past seven and the line starts to climb. At ten a full meeting with the door shut pushes CO₂ past 1,300 ppm in under an hour. Someone opens the window, and within minutes the line drops by half. When everyone leaves at six, the room empties itself overnight.
A CO₂ meter shows one number to whoever happens to look. A CO₂ data logger shows the whole day. This is a day from the PitCanary dashboard.
How fast does CO₂ rise in a meeting room?
In a closed 12 m² meeting room with four people, CO₂ rises about 39 ppm a minute and passes the office line in about twenty minutes. A small meeting room holds less air than it looks, and the sum is simple.
Worst case, with doors and windows shut. A real room leaks a little, so it climbs slower. The shape is the same.
A one-hour meeting in a small room is fine for the first quarter and stale for the rest. CO₂ never drops on its own while people are inside. Back-to-back bookings stack one meeting's air on top of the next.
How long does your room last?
- Rise
- +39ppm a minute, closed
- Until orange
- 20min
- Until red
- 35min
CO₂ per person from Persily and de Jonge, 2017: about 18.7 litres an hour for an adult at a desk and 10.4 asleep. The ventilation figures are rules of thumb. A PitCanary in the room replaces them with the real curve.
How do you lower CO₂ levels in a room?
You lower CO₂ levels by bringing outdoor air in: five to ten minutes with the windows wide open clears a room faster than a window on the latch all day. How you ventilate matters more than how long.
-
Open wide, brieflyFive to ten minutes with the windows fully open clears more than a window on the latch all day. The walls keep their warmth.
-
Open across the roomWindows or a door on opposite sides let the air flow straight through. One window on one side works, but slowly.
-
Leave a gap between meetingsTen minutes empty with the door open resets a small room. Back-to-back bookings never let it recover.
-
Turn up the ventilationWith mechanical office ventilation, the dashboard shows which rooms turn orange every day. So the setting can follow the use.
If a room is always orange whatever you do, it is too small or too busy for its ventilation. That is a finding, not a failure. The history on the dashboard is what makes the case for a change.
Which CO₂ sensor should a CO₂ monitor have?
A CO₂ monitor should have an NDIR or photoacoustic CO₂ sensor, the two types that measure carbon dioxide itself. Inside an NDIR sensor is a small chamber with an infrared light. CO₂ absorbs one colour of infrared, so the less light gets through, the more CO₂ is in the air. A photoacoustic sensor does the same in a smaller space, with pulsed light and a tiny microphone.
Not every device with a CO₂ number measures CO₂. Many cheap air quality meters have a VOC sensor and calculate an "equivalent CO₂" from it, labelled eCO₂. That number follows perfume, cleaning products and cooking as much as people. It can say 400 ppm in a full room. If a device does not name an NDIR or photoacoustic CO₂ sensor, it is guessing.
The second thing to check is memory. A CO₂ monitor shows the air now. A CO₂ data logger also keeps every reading, so you can look at yesterday, compare rooms, or show a landlord or a manager what happened. Most devices do one of the two.
A CO₂ meter is not a carbon monoxide alarm. CO is a poisonous gas from faulty boilers and stoves, and it needs its own detector.
PitCanary has a photoacoustic CO₂ sensor, keeps a reading every minute, and is not a carbon monoxide alarm.
How does PitCanary monitor CO₂?
PitCanary monitors CO₂ and logs it: the light on the base shows the state of the room now, and a reading every minute goes to the dashboard and is kept. So the room can act without anyone opening an app, and every day can be read back room by room.
CO₂ is never measured alone. Temperature, humidity, light, sound and presence are read on the same minute. When a room goes stale you see why: a full room, a closed window, or the heating that made someone shut it. A plain CO₂ meter cannot tell you that, because it knows one number.
Read together, the afternoon explains itself. The room filled up at 14:30, CO₂ and temperature climbed with it, and one open window at 16:00 brought both back.
What is a CO₂ data logger?
A CO₂ data logger is a CO₂ monitor with a memory: it stores every reading, so you see the whole day instead of one moment. Most CO₂ meters show the number now and forget it a minute later. PitCanary keeps it, with the temperature, humidity, light and sound next to it, in a log for the room. Months later you can still see which days went stale, for how long and why.
That log is yours, not ours, and getting it out costs nothing. There is no export fee and no paid tier for your own history. The PitCanary API serves the same readings as JSON.
| Time | CO₂ ppm | Temp °C | Humidity % | Light lx | Sound dBA | Occupancy |
|---|---|---|---|---|---|---|
| 15:26 | 852 | 22.5 | 47 | 620 | 44 | High |
| 15:27 | 855 | 22.5 | 47 | 610 | 47 | High |
| 15:28 | 857 | 22.6 | 48 | 600 | 45 | High |
- On the timelineEvery hour of every day, with what changed and why.
- As a downloadBy room, day or month, as CSV.
- Through the APIInto your building system, BI tool or app.
So you read a day the way you read a log. Not a number at this minute, but what changed and why.
- From 10:00 to 11:15: CO₂ to 1,320 ppm in one meeting. From 720 ppm at 10:00 to 1,320 at 11:00, rising 100 ppm every 10 minutes with the room busy and voices all through. Over the office line from 10:50. A busy meeting room turns stale within the hour. Ten minutes of open window cleared it.
- 11:01: window opened. CO₂ 1,320 to 600. Back under the office line within five minutes.
What are acceptable CO₂ levels per room?
Acceptable CO₂ levels depend on the room: EN 16798-1 allows 800 ppm above outdoor in an office or meeting room and 550 ppm above outdoor in a bedroom. Most CO₂ meters have one alarm for every room. But an office for four is held to a different standard than a gym, and both differ from a bedroom. This table is the reference: one row per room, the CO₂ limit and how it is read.
| Room | Limit | How it is read |
|---|---|---|
| Office and meeting room | 800 ppm above outdoor, about 1,220 ppm | While the room is in use |
| Hotel lounge | 800 ppm above outdoor | No workplace limit; the comfort standard applies |
| Bedroom | 550 ppm above outdoor, about 970 ppm | Overnight, with the door closed, most bedrooms exceed it |
| Gym and sports hall | 800 ppm above outdoor | Higher breathing rates, so ventilation needs are higher |
| Any workplace, absolute ceiling | 5,000 ppm over eight hours | A safety limit, not a comfort one; indoor rooms rarely come near it |
Sources: EN 16798-1:2019, Annex B, default CO₂ levels above outdoor (offices and lounges, bedrooms, sports halls); EU Directive 2006/15/EC (workplace exposure limit).
PitCanary knows fifteen room types and judges each against its own band. Set the room type once. The light, the timeline and the Room score do the rest. The indoor climate page puts CO₂ next to the other four numbers for every room type.
Questions about CO₂ monitors and CO₂ levels
What CO₂ level is too high in an office?
Above about 1,220 ppm, the line of EN 16798-1 Category II: 800 ppm above outdoor air at about 420 ppm. Germany's ASR A3.6 draws a stricter line at 1,000 ppm, and PitCanary uses that line for offices and meeting rooms. Above either line the room needs more fresh air.
Which CO₂ sensor should a CO₂ monitor have?
An NDIR or photoacoustic sensor, the two types that measure carbon dioxide itself with infrared light. A VOC sensor that reports "eCO₂" only estimates it. If a monitor does not name an NDIR or photoacoustic sensor, it is guessing. PitCanary uses a photoacoustic sensor.
What are normal CO₂ levels indoors?
Between about 420 ppm, the outdoor level, and 1,000 ppm in a room in use. An empty room settles back to outdoor air overnight. A full meeting room with the door shut can pass 1,300 ppm within the hour, which is why a day of readings says more than one.
How do I know if the office ventilation is enough?
Log CO₂ for a normal week. If a room stays under about 1,220 ppm while in use, the ventilation keeps up. If it turns orange every afternoon whatever you do, the room is too small or too busy for its ventilation. The log is what makes the case for a change.
How quickly does CO₂ rise in a closed meeting room?
In a 12 m² room with four people and no ventilation, CO₂ passes the office limit in about twenty minutes. Based on about 18 litres of CO₂ per person an hour, Persily and de Jonge, 2017.
What is the fastest way to bring CO₂ down?
Open the windows wide for five to ten minutes, on opposite sides of the room if you can. That clears more than a window left ajar all day.
Where should a CO₂ monitor go in a room?
Where people breathe. About the height of a seated head, away from windows, doors and vents, and not right next to one person. Near a window it reads outdoor air. Next to a desk it reads one person.
What is the difference between a CO₂ monitor and a CO₂ data logger?
A monitor shows the CO₂ now. A data logger also stores every reading, so you can see how long a room was stale and when. PitCanary does both.
Can I download my CO₂ data?
Yes. PitCanary keeps every reading of every room for as long as you use it. Download it by room, day or month, or pull it via the API. It is your data, so it costs nothing.
Is a CO₂ meter the same as a carbon monoxide alarm?
No. A CO₂ meter measures carbon dioxide, the gas people breathe out, to show how fresh the air is. A carbon monoxide alarm detects CO, a poisonous gas from faulty boilers and stoves. PitCanary is not a carbon monoxide alarm.
What CO₂ level is dangerous?
In the UK the workplace exposure limits for CO₂ are 5,000 ppm averaged over eight hours and 15,000 ppm over fifteen minutes (HSE, EH40/2005). An office never gets near that: there CO₂ is a sign of stale air, and the HSE calls a room that stays above 1,500 ppm poorly ventilated. PitCanary is not a safety alarm.
Are CO₂ monitors a legal requirement?
No law names a CO₂ monitor, but in the UK every employer must ventilate an enclosed workplace with enough fresh air, under regulation 6 of the Workplace (Health, Safety and Welfare) Regulations 1992. The HSE suggests a CO₂ monitor as a way to find the rooms that fall short.
Does a CO₂ monitor detect gas leaks?
No. A CO₂ monitor measures carbon dioxide only. A natural gas leak needs a gas detector and a faulty boiler needs a carbon monoxide alarm. PitCanary is neither.
What causes high CO₂ levels at home?
People breathing in a closed room. A home office with the door shut or a bedroom at night can pass 1,000 ppm within hours, because a small room holds little air for one or two people. A window open a little, or a short airing every hour, brings it down.
How many CO₂ monitors do I need?
One for every room where people spend hours: each office, meeting room and home office. CO₂ differs from room to room, so one monitor in the hallway says nothing about the meeting room. A PitCanary costs €149 excl. VAT, and the dashboard is free for one device.