PitCanary is available from January 2027. Subscribe to the newsletter and we email you the day ordering opens. Subscribe

PitCanary

Lux meter and office lighting per room

A lux meter measures how much light falls on a surface, in lux, and an office desk needs 500 lux for reading and screen work under EN 12464-1. PitCanary is an indoor climate monitor for offices, meeting rooms and home offices that works as a lux meter in every room, reading brightness, light colour, daylight and flicker every minute. A device costs €149 excluding VAT, and the dashboard for one device is free.

In short

About a fifteen-minute read · Updated
What it measures
Lux on the desk. Its colour, daylight or lamp, flicker.
Office desk
500 lux for reading and screen work, EN 12464-1.
By the window
1,000 lux or more. Three metres in, often under 200.
For the body clock
Bright, cool light by day. Dim, warm light in the evening.
Flicker
Daylight never flickers. Cheap LED drivers do, at 100 Hz.
A lux meter
One spot, one moment. PitCanary reads it every minute.
PitCanary
Logs lux, colour, daylight and flicker every minute.
Your data
Every reading is yours. Download it or use the API, free.

What is lux, and what else matters in office lighting?

Lux is the unit of how much light lands on a surface: one lumen spread over one square metre is one lux. Light has three things to it that matter in a room, brightness in lux, colour in kelvin and flicker in hertz, and a lux meter only reads the first.

  • Brightness500lux

    One lux is roughly the light of a candle one metre away. A desk needs about 500 lux to read and type without strain. Outdoors, even on a grey day, there is far more, which is why a window is worth more than any lamp.

  • Colour4,000K

    Low numbers are warm and yellow, like a candle at 2,000 K or a warm white lamp at 2,700 K. High numbers are cool and blue-white, like an overcast sky at 6,500 K. Office lamps sit around 4,000 K. The body reads cool, bright light as daytime and warm, dim light as evening.

  • Flicker100Hz

    Daylight is steady. Lamps are not always: a cheap LED driver switches on and off a hundred times a second. Too fast to see, not too fast to feel. Flicker is a known cause of headaches and tired eyes.

What you notice

Eye strain
Under 300 lux on the desk, the bottom of PitCanary's office band. Squinting at paper, leaning into the screen, tired eyes by four.
The afternoon slump
Too little bright light in the morning. The body clock never got its daytime signal, so the afternoon feels like evening.
Poor sleep
Bright, cool light in the evening. Screens and office lamps after seven tell the body it is still day.
Headache
Flicker from the lamps, or glare from a window straight into the screen. Gone when you leave the room.

You cannot see 300 lux or 100 Hz. PitCanary reads both every minute, and tells you whether the room was dark and whether the lamps flicker.

Sources: EN 12464-1:2021; Brown et al., 2022; IEEE 1789-2015; Boubekri et al., 2014.

How many lux does an office need?

An office desk needs 500 lux for reading, writing, typing and screen work, according to EN 12464-1. PitCanary reads an office as too dark below 300 lux, the bottom of its office band, and above about 1,000 lux at the desk glare on the screen becomes likely. A lux meter shows a number: 180, 420, 1,100. None of them tells you whether to switch the lamps on or pull the blind.

So PitCanary cuts the scale into three bands, and the base of the device breathes the colour of the band. Everyone in the room sees at a glance whether the light is right for the work. The light score follows the room type: a reception needs less than a desk, and a hotel room at ten at night should be dim.

Orange

Too dark. Switch the lamps on or move to the window.

Green

Right for the task.

Orange

Glare. Pull the blind.

By day the light should sit towards the cool end. In the evening, towards the warm end.

Lux levels per room type from EN 12464-1. The daytime and evening targets for the body clock from Brown et al., 2022. Each market reads the bands against its own standard; the colours stay, the edges move.

What does a day of office lighting look like?

A day of office lighting is daylight in the middle and lamps at the edges, and a log every minute shows where the two meet. Take one day in an office with a window to the south-west. Nothing until half past seven, when the first lamps come on. From nine the daylight climbs and the lamps barely matter. Around one the sun comes round and the desk by the window gets 1,800 lux, far above the 1,000 where glare starts. By four the daylight fades and the lamps carry the room again. At six everyone leaves. The lamps stay on until eleven.

Open office, window desk · TuesdayLux on the left, colour in kelvin on the right
  1. 1Lamps on
  2. 2Sun on the desks
  3. 3Everyone left, lamps on until 23:00
Light at a desk by a south-west window over 24 hours. Lamps on from 07:30 at about 300 lux. Daylight climbs from nine, the sun reaches the desk after 13:20 and the total peaks at about 1,800 lux. Daylight fades by four, everyone leaves at six and the lamps stay on until 23:00. The colour of the light runs from 4,000 K under the lamps to about 6,000 K at midday.

A lux meter reads one spot at one moment. The day shows the three things that matter: where the light came from, when it was too little, and when it was too much.

What is circadian lighting?

Circadian lighting is light that follows the body clock: bright and cool by day, at least 250 melanopic lux at the eye, and dim and warm in the evening, under 10 (Brown et al., 2022). Brightness and colour are two numbers, and two numbers are hard to read together. So the dashboard draws a day of light as one shape. The floor is the day, from midnight to midnight. The depth is the colour, warm at the front, cool at the back. The height is how bright. Daylight stands up as a tall, cool peak in the middle of the day. Lamps lie low and warm at the edges. One look tells you whether this room lives on daylight or on lamps, and whether the evening turns warm.

An example day. Height is brightness, depth is colour temperature. PitCanary tells daylight from lamps by its high infrared share and the absence of flicker. Colour runs from 2,000 K warm to 8,000 K cool. Daylight peaks at about 1,500 lux at 13:50. The lamps stay at 4,000 K from 07:30 to 23:00.

The dashboard builds it from the lux, kelvin and flicker values the device already sends.

How far does daylight reach into an office?

Daylight falls off fast: a desk one metre from a window can have 1,000 lux on a grey day, and a desk three to four metres in often has under 200. Fill a room with desks and the sum is simple.

1,000 luxone metre from a window on a grey day, before any lamp is on
Under 200lux three to four metres in, the same day, same window
500 luxwhat a desk needs for screen work, EN 12464-1
Row 3the row that works under the lamps all day, winter and summer

A sketch of how daylight falls off, not a measurement. A real room depends on the window size, the glass and what is opposite; a reading at the desk shows how far it reaches.

That is why the desks by the window go first, and why the back row has the lamps on in July. A lux meter at one desk tells you that desk. A reading every minute, all year, tells you which rooms never see daylight at all.

How do you improve office lighting?

Improve office lighting in three steps: move the work towards the window, warm the lamps in the evening, and replace lamps that flicker. Light is the easiest thing in a room to fix, because most of the fixes are furniture and a switch. Start with the desks. Close to a window they get most of their 500 lux from the sky for much of the year, so put the work there and turn the desks so the window is at the side, not in the screen.

Then the colour. Keep the lamps at 4,000 K or cooler until early afternoon, and warmer and dimmer after that. Tunable lamps do it on a schedule. And switch the lamps off when the room is empty: lamps that burn in empty rooms every evening show up in the log, and an occupancy sensor or a schedule ends it.

Last, check the lamps for flicker. Film them with a phone camera. Rolling bands mean a cheap driver. Replace the driver, not the room.

  • Steady or switchingA clean driver gives steady light. A cheap one switches it on and off a hundred times a second. Too fast for the eye, not for a phone camera.

If a desk is always orange whatever you do, it is too far from the window for its task. That is a finding, not a failure. The history shows which desks, and the lamp schedule shows which hours.

What does a lux meter measure, and what does it miss?

A lux meter, or light meter, measures how much light falls on a surface, in lux, at one spot and one moment. You hold it flat on the desk, facing up, and read the number. A good one has a white dome over the sensor so it catches light from every angle. The phone apps do the same with the camera and are often far off, because a camera is built to make pictures, not to count light.

A lux meter answers one question: how bright is it here, now. It does not tell you the colour of the light, whether it is daylight or lamp, whether it flickers, or what it was at nine this morning. For a one-off check of a desk it is the right tool. For knowing whether a room is lit well through the year, it is a snapshot.

PitCanary reads lux the same way, every minute, with the colour, the daylight share and the flicker next to it. It reads the light where it sits, so put it where the work is.

How does PitCanary measure light?

PitCanary reads the light every minute through a window in its lid: brightness in lux and colour in kelvin from one reading, plus the daylight share and flicker. Daylight is told apart from lamp light by its high infrared share and the fact that daylight never flickers. Whether the room is in use is read on the same minute. So the dashboard knows not only how bright the room was, but whether the light was the sun or the lamps, and whether anyone was there for it.

Open office, window desk · one dayEvery line read on the same minute
13:20 · sun on the desks
Light1,800 lx peak
Colour6,100 K midday
Daylight85 % share
OccupancyEmpty from 18:00

Read together, the day explains itself. Daylight carried the room from nine to four, the lamps ran from half past seven to eleven, and for five of those hours nobody was in.

Light
Lux and colour temperature from one reading, every minute.
Daylight or lamp
Told apart by infrared share and flicker. No smart plugs needed.
Flicker
Read in short bursts every minute, as a percentage and a frequency. Clean driver or not.
Lamps
Lights on and lights off, as events on the timeline.

Can you log light levels over time?

Yes: PitCanary is a light logger that keeps every reading, where most lux meters show the number now and forget it a minute later. Every light reading, lux, colour, daylight share and flicker, goes into a log for the room, with the temperature, air quality and sound next to it. Months later you can still see which hours stayed dark, for how long and why.

That log is yours, not ours. Getting it out costs nothing: no export fee, no paid tier for your own history, and the PitCanary API for your own systems.

Open office, window desk44,640 readings this month, one per minute
TimeLight lxColour KDaylight %FlickerOccupancy
13:201,1205,82073NonePresent
13:211,1605,79074NonePresent
13:221,2105,76075NonePresent
  • On the timelineEvery hour of every day, with what changed and why.
  • As a downloadBy room, day or month, as CSV.
  • Through the APIInto your building system, BI tool or app.

So you read a day the way you read a log. Not a number at this minute, but what changed and why.

Insights / HQ / Room 3A reading every minute
Timeline · TuesdayDark at first, then glare: one day of light
  1. 14:40: sun on the west desks for 1 h 10. Up to 1,500 lx at the wall from 13:30 to 14:40, well over the 500 lx screens are comfortable at. Blinds down at 14:40. Glare on the screens, and the sun added to the warmth.
  2. 14:40: dark at first, then glare up to 1,500 lx. A grey start: with the lamps on from 08:05 the room stayed under the desk-work line, 300 lux, until 09:00. Daylight took over at 11:05 and the lamps went off; sun on the west desks from 13:30, up to 1,500 lx. Too dark at the start, glare after lunch. A desk lamp in the morning and the blinds at 13:30 would even the day out.
  3. 13:02: lights on.
  4. 12:12: lights off.

What lux level does each room need?

Each room type needs its own lux level: 500 lux on an office desk under EN 12464-1, and under 10 melanopic lux at the eye in a bedroom in the evening. A desk, a hotel room in the evening and a wine cellar want very different light, and a bedroom at night should have almost none. This table is the reference: the room, the lux it needs on the work surface, and what to watch.

RoomLux on the taskWhat to watchStandard or guidance
Office desk, screen and paper300 lx or moreGlare from a window behind or in front of the screen500 lx on the task (EN 12464-1)
Meeting room300 lx or moreDimmable for presentations500 lx on the task (EN 12464-1)
Reception200 to 750 lxEnough to read a form at the counterEN 12464-1, by task
Hotel room50 to 750 lx, under 1 lx at nightWarm and dim at night: the night band is darker stillPitCanary's band
Hotel lounge, evening100 lx or moreWarm colour from seven o'clockPitCanary's band
Bedroom, eveningUnder 10 lx, under 1 lx at nightDim and warm, no cool whiteUnder 10 melanopic lux at the eye (Brown et al., 2022)
Wine cellarUnder 10 lxLight spoils wine over the yearsDark; trade consensus, no formal standard
ArchiveUnder 50 lxLow light protects paper and inkISO 11799: light by cumulative exposure, off when nobody is in

The band column is the one PitCanary reads that room type against, from its room type registry. Sources for the guidance column: EN 12464-1:2021 (workplaces); Brown et al., 2022 (evening and night); ISO 11799 (archives); the wine storage trade consensus, which is not a formal standard (wine cellars). The hotel room and hotel lounge bands are PitCanary's own.

PitCanary knows fifteen room types and reads the light against what each one needs. Set the room type once. The light, the timeline and the Room score do the rest. Light is one of five parts of a good indoor climate, 18 of the Room score's 100 points by default.

Questions about lux meters and office lighting

How many lux does an office need?

500 lux on the desk for reading, typing and screen work, EN 12464-1, which sets its own figure for each other task. Older staff and fine work need more. PitCanary flags an office under 300 lux, its own band.

What is lux?

Lux is the unit of how much light lands on a surface: one lumen spread over one square metre is one lux. Lumen is how much light a lamp gives off; lux is how much of it reaches the desk. An 800-lumen bulb lights a small desk well and a large room badly.

What is a lux meter?

A device that reads how much light falls on a surface, in lux. You lay it flat where the work is, facing up. It gives one reading at one spot at one moment. PitCanary reads lux every minute, with the colour of the light and whether it flickers.

What is circadian lighting?

Light that follows the body clock: bright and cool by day, at least 250 melanopic lux at the eye, and dim and warm in the evening, under 10. A window seat gives the daytime dose and most lamps do not. Brown et al., 2022.

Which colour temperature is best for an office?

Around 4,000 K during the day, the neutral white most office lamps use. Cooler light, 5,000 to 6,500 K, in the morning helps the body clock. Warmer, 2,700 to 3,000 K, after six in rooms people sit in late.

Is LED flicker bad for you?

It can be. Flicker at 100 Hz from a cheap driver is too fast to see but is linked to headache, eye strain and tiredness. LED lamps sold in the EU since 2021 must meet flicker limits, Regulation 2019/2020. Older and cheap lamps often do not. Film the lamp with a phone: rolling bands mean flicker.

Is a phone lux meter app accurate?

Rarely. A phone camera is built to make pictures, not to count light, and apps are often far off. Fine to tell dark from bright, not fine to check a desk against 500 lux.

Can I download my light data?

Yes. Every lux, colour, daylight and flicker reading, by room, day or month, or via the API. It is your data, so it costs nothing.

Work in good light. Sleep in the dark.

One PitCanary tracks brightness and light colour through the day, so you can see when the room is wrong for what it is for. The dashboard for your first room is free.