PitCanary is available from January 2027. Subscribe to the newsletter and we email you the day ordering opens. Subscribe

PitCanary

Hygrometer and humidity logger for every room

A hygrometer measures the relative humidity of the air, in percent, and a room should sit between 30 and 60 percent. PitCanary is a hygrometer and humidity data logger for offices, home offices and holiday homes that reads humidity every minute, next to temperature and the dew point. One PitCanary costs €149 excl. VAT, and the dashboard for one device is free.

In short

About a seventeen-minute read · Updated
What it measures
Water in the air, as a share of what it could hold.
The band
30 to 60 percent. PitCanary's band for offices and hotel rooms; 40 to 60 is the ideal.
Too dry
Under 30. Dry eyes, static shocks. Every office in January.
Too humid
Above 60 for weeks. Mites, then mould on the cold walls.
Why winter is dry
Heating adds no water. Warm air holds more, so it reads lower.
A hygrometer
One spot, one moment. PitCanary reads it every minute.
PitCanary
Logs humidity every minute, with temperature and dew point.
Your data
Every reading is yours. Download it or use the API, free.
1litre an hourWhat the office needed. The humidifier did a cup.

Why measure humidity in an office? Because a humidifier without a hygrometer is a guess.

In many of the offices I have worked in, the air was dry for months, and nobody knew how dry because nothing measured it. What everybody knew was that by February eyes were dry and the door handles gave shocks. After a day of demos and sales calls I felt my voice go. Talking all day in that air wore it down.

In one of them a humidifier was bought, a proper machine, for the part of the floor where I sat. It hummed, it steamed, it needed filling, and it did not really help. Nobody could tell why, because nothing measured whether the air had changed. Now I know the sum: that office needed about a litre of water an hour, all day. The machine did a cup.

A PitCanary would have shown it in the first week: dry every working day from November to March, and a line that did not move when the humidifier ran. Then it would have been clear what to buy, or that the problem was the ventilation and not the air.

What is relative humidity?

Relative humidity is the amount of water in the air as a percentage of what the air could hold at its temperature. That last part is the whole story, because warm air can hold far more water than cold air. When the heating takes outdoor air at 0 °C and 80 percent and warms it to 21, the same water is now only 20 percent of what the air could carry. Nothing was taken out; the air just got bigger. That is why every heated room is dry in winter, and why the ventilation that keeps the CO₂ down makes it drier still.

  • Outdoor air, 0 °C80%

    Eight drops of water in air that holds ten.

  • The same air, 21 °C20%

    The same eight drops in air that now holds forty.

The other way round happens where water is made: a shower, a kettle, a room full of people. Every breath out carries water, so shut the door and the air fills up. If a wall or a window is colder than the air can carry, the water lands there. That is condensation, and condensation that stays is mould.

What you notice

Dry eyes and throat
Under 30 percent. Screens feel harder to look at, the throat is scratchy by four, voices get tired.
Static
Under 30 percent. Shocks from the door handle, hair that stands up, paper that sticks.
Condensation
Water on the inside of the window in the morning. The air is fuller than the window is warm.
A musty smell
Somewhere a corner has been above 70 percent for weeks. The mould is already there.

You notice dry air by the shocks and damp air by the smell. PitCanary logs both at the moment they start, months before the smell.

Sources: EN 16798-1:2019; ASHRAE 55; Sterling et al., 1985; WHO Guidelines for Indoor Air Quality: Dampness and Mould, 2009; Lowen et al., 2007 on flu survival in dry air.

What humidity should a room be?

A room should be between 30 and 60 percent relative humidity, and 40 to 60 percent is the ideal. That is PitCanary's band for offices, meeting rooms and hotel rooms: 30 as the dry edge, and 60 as the ceiling of EN 16798-1 Category II and ASHRAE 62.1. The 40 to 60 ideal comes from the Sterling chart of 1985, and EN 16798-1 Category II itself allows 25 to 60.

Humidity is one of the few numbers where both ends are wrong. Too low is a people problem, and too high is a building problem. So the scale has orange on both sides.

Orange on the dry side in January means the heating and the ventilation are doing what they do. Orange on the damp side in a hotel room in the morning means open the window now, not at noon. Red on the damp side for days is when damp and mould become the question.

Red

Very dry.

Orange

Dry side. Inside PitCanary's band down to 30, dry below it.

Green

The ideal.

Orange

Damp. Ventilate.

Red

Wet. Mould risk on cold surfaces.

The 40 to 60 ideal from Sterling et al., 1985. PitCanary's band is 30 to 60, and EN 16798-1 Category II allows 25 to 60. Mould risk from ISO 13788 and WHO 2009.

Why is the air so dry in an office in winter?

Office air is dry in winter because heating warms cold outdoor air without adding water, so its relative humidity falls. This is one Tuesday in January in an open office. Overnight the room sits at 34 percent and 17 °C. At seven the heating starts, the temperature climbs to 21 and the humidity falls to 26 without a drop of water leaving the room. By eleven, with the ventilation running and twenty people at their desks, it is 22. At one, lunch, the ventilation drops to a lower setting and the line creeps back to 27. By four it is 21, the driest of the day, with the outdoor air at 0 °C and 85 percent outside the window.

Open office · a Tuesday in JanuaryHumidity in % on the left, temperature in °C on the right
  1. 1Heating on
  2. 2Ventilation to low
  3. 3Driest moment
Humidity in an open office on a January day, with the indoor temperature and the outdoor humidity. Overnight 34 percent at 17 °C. The heating starts at 07:00, the room warms to 21 °C and the humidity falls to 22 percent by eleven. The ventilation goes to low at 13:00 and the line recovers to 27, then falls to 21 percent at 16:00, the driest moment. Outdoors the humidity stays between 80 and 90 percent.

A hygrometer on the wall would have said 22 to whoever looked. A humidity data logger shows the office is dry every working day from November to March, and that the humidifier in the corner never moved the line.

How big a humidifier does an office need?

An open office of 300 m³ needs about 1.1 litres of water an hour to stay 20 points more humid, while a desk humidifier delivers about 0.3. Dry air is a volume problem, and most humidifiers are bought by the look of them. The sum is simple.

300 m³an open office of 115 m² with a 2.6 m ceiling
3.7 gwater per m³ for every 20 points of humidity at 21 °C
1.1 l/hto hold the office 20 points higher while the ventilation replaces the air about once an hour
0.3 l/hwhat a desk humidifier delivers

Rule of thumb. A real office leaks more or less air than this; the shape of the sum is the same.

That is why the machine in the corner never moves the line. The right fix is often not a humidifier at all, but ventilation that takes in no more cold air than it needs, or heat recovery that keeps the moisture in.

Where will it condense?

Dew point
10.2°C
At the surface
88% humidity
Stays dry under
45% in the room
Mould risk

Dry to the touch, but above 80 % at the surface. Kept up for weeks, mould grows here.

The dew point is calculated with the Magnus formula. The surface temperatures are typical values; a PitCanary in the room reads the air, not the wall.

What humidity causes mould?

Mould grows where a surface stays above about 80 percent humidity for weeks, which happens in a room above 60 to 70 percent with cold walls (ISO 13788). Mould does not need a leak. It needs three things: water in the air, a surface cold enough to collect it, and weeks. The room itself can sit at 60 or 65 percent. But the wall behind the wardrobe or the corner where two outside walls meet is several degrees colder than the air, and at that surface the same water is at 80 percent or more. Hold it there for weeks and mould spores, which are in every room, start to grow.

That is why mould grows in the same places in every building, and why it comes back after cleaning when nothing else changes. The en-suite ceiling that never dries between guests. The hotel room that wakes at 70 percent every winter morning. The window frame that is wet at seven and dry by noon, every day from November to March.

Where it grows first

Outside corners
Where two outside walls meet, often near the floor or ceiling. The coldest spot in most rooms.
Behind furniture
A wardrobe or bookcase against an outside wall. No warm air reaches the wall behind it.
Window frames
The seal and the bottom of the frame, where condensation runs down. Black spots in the silicone first.
Bathroom ceilings
An en-suite that stays above 70 percent between showers. Grey dots that spread along the edge.

Mould is a building problem first, and it can become a health problem. The WHO links damp and mould in buildings to more coughing, wheezing and asthma symptoms, especially in children and people who already have asthma. The smell comes before the spots, and the spots come long after the humidity was too high.

PitCanary logs the humidity and the dew point of the room every minute and counts the hours the room spends above 70 percent. A hotel room that is damp one morning is weather. A hotel room that is damp every morning for three weeks is a mould risk, and the log shows it before the smell does.

Sources: ISO 13788 (80 percent surface humidity as the mould criterion); WHO Guidelines for Indoor Air Quality: Dampness and Mould, 2009.

How do you fix dry air or damp in a room?

Dry air in winter needs water added or less cold air let in, and damp air needs a short, wide-open window. The two halves of the year want opposite fixes, which is why a log through the year is worth more than any single measurement.

  • Winter: size the humidifier to the roomA litre an hour for an open office, not a desk unit. Or ask the installer for heat recovery, which warms the incoming air without drying it further.
  • Winter: do not over-ventilateEvery cubic metre of cold outdoor air is a cubic metre of dry indoor air. Ventilate for the CO₂, not more.
  • Hotel room and en-suite: open wide, brieflyTen minutes with the window wide open after a shower or in the morning takes the water out. A window on the latch all day takes the heat out.
  • Cold corners: warm the wall, not the airMould grows where the wall is cold, behind the wardrobe, in the outside corner. Move the furniture ten centimetres off the wall and keep the room above 18.

If a room is orange on the dry side every winter day, the ventilation is the cause. If it is orange on the damp side every morning, the window is the fix. The log tells you which.

What is a hygrometer?

A hygrometer is a device that measures the relative humidity of the air at the sensor, in percent. Old ones used a hair that stretches when damp. A modern one is a small digital humidity sensor that reads humidity and temperature together, because one is meaningless without the other. A cheap one can be several points out, and a few points is the difference between "fine" and "too dry".

You can check any hygrometer with salt. A wet, saturated heap of table salt in a sealed box, with the hygrometer next to it, reads 75 percent after a few hours. If yours says 70 or 80, you know what to add.

What a hygrometer does not know is time. Humidity in a room moves with the heating, the weather, the shower and the people, and the number at four in the afternoon says nothing about the morning. It does not know the temperature of the wall, which decides whether the water condenses. And it does not know what it is outside, which decides whether opening the window helps or hurts.

PitCanary reads the humidity the same way, every minute, with the temperature, the CO₂ and the dew point next to it. Put it where the people are, not in the bathroom.

How does a humidity monitor differ from a hygrometer?

A humidity monitor is a hygrometer that reports continuously to a screen or a dashboard, so you see the humidity change instead of one reading. PitCanary reads humidity every minute with a digital humidity and temperature sensor, and posts it to the dashboard every minute. It is never read alone: temperature, CO₂ and presence are read on the same minute, and the dew point is computed from temperature and humidity. So when a room runs dry, you see why: the heating ramp, the ventilation stepping up, twenty people and no window. When a room runs damp, you see that too: the hotel room at seven, the meeting room after a full afternoon.

Open office · one winter dayEvery line read on the same minute
07:00 · heating on
Humidity21 % low
Temperature21.4 °C
OccupancyHigh from 08:00

Read together, the day explains itself. The water in the air never changed. The heating did.

Humidity sensor
A digital humidity and temperature sensor, the two read together.
Interval
A reading every minute, posted every minute.
Context
Temperature, CO₂ and occupancy on the same minute, with the dew point computed.
Logging
Every reading kept, export by room, day or month.

What is a humidity data logger?

A humidity data logger is a hygrometer with a memory: it stores every reading, so you see weeks of humidity instead of one moment. Most hygrometers show the number now and forget it a minute later. PitCanary keeps it, with the temperature and the dew point next to it, in a log for the room. Months later you can still see which weeks went dry, for how long and why.

That log is yours, not ours, and getting it out costs nothing. There is no export fee and no paid tier for your own history. The PitCanary API serves the same readings as JSON.

Open office44,640 readings this month, one per minute
TimeHumidity %Temp °CDew point °COccupancy
15:582121.4−1.9High
15:592121.4−1.9High
16:002121.3−1.9High
  • On the timelineEvery hour of every day, with what changed and why.
  • As a downloadBy room, day or month, as CSV.
  • Through the APIInto your building system, BI tool or app.

So you read a day the way you read a log. Not a number at this minute, but what changed and why.

Insights / HQ / Open officeA reading every minute
Timeline · a Tuesday in JanuaryEvery change, with the readings at that moment
  1. 13:00 to 16:00: dry all afternoon. From 27% at 13:00 to 21% at 16:00, with the heating on and the ventilation at high. Under 25% from 14:10. The humidifier ran from 14:00; the line did not move. It pulled the Room score to 76, from 84.

What is the right humidity for an office, a home office or an archive?

The right humidity is 30 to 60 percent for an office, a meeting room, a home office and a bedroom, 35 to 55 for an archive and 60 to 70 for a wine cellar. A hygrometer has one number for every room. But a wine cellar at 65 percent is right and an office at 65 is damp. This table is the reference: the room, the band, what to watch and where the band comes from.

RoomBandWhat to watchSource
Office30 to 60 %, ideally 40 to 60Under 30 from November to March; it is the heating, not the weatherPitCanary's band; the ideal after Sterling et al., 1985
Meeting room30 to 60 %, ideally 40 to 60A full afternoon pushes it up; a window brings it backPitCanary's band; the ideal after Sterling et al., 1985
Hotel room or bedroom30 to 60 %, ideally 40 to 60Sleepers add water to the air all night; open the window in the morning, not the eveningPitCanary's band
Wine cellar60 to 70 %Steady matters as much as the number: too dry dries the corks, too damp grows mould on the labelsPitCanary's band; trade consensus, no formal standard
Server roomBelow 60 %, dew point under 15 °CCondensation on cold intake airASHRAE TC 9.9, recommended envelope
Archive35 to 55 %, steadyThe swing matters more than the number; paper and wood move with itPitCanary's band; daily swing under 5 points, ISO 11799

Sources: EN 16798-1 Category II and ASHRAE 62.1 for the 60 percent ceiling (Category II allows 25 to 60); Sterling et al., 1985, for the 40 to 60 ideal; ASHRAE TC 9.9, recommended envelope (server rooms); the wine storage trade consensus, which is not a formal standard (wine cellars); ISO 11799 (the archive's daily swing). The office, hotel room, wine cellar and archive bands are PitCanary's own.

PitCanary knows fifteen room types, the wine cellar and the archive among them, and reads each against its own band. Set the room type once. The light, the timeline and the Room score do the rest. The indoor climate page puts humidity next to temperature, CO₂, light and sound.

Questions about hygrometers and indoor humidity

What humidity should a room be?

Between 30 and 60 percent, and ideally 40 to 60 (Sterling, 1985). Below 30 the air is dry enough to notice; above 60 for weeks, mites and mould get going. 30 to 60 is PitCanary's band for offices and bedrooms; the 40 to 60 ideal comes from the Sterling chart of 1985, and EN 16798-1 Category II allows 25 to 60.

What is the ideal humidity for an office?

30 to 60 percent, ideally 40 to 60 (Sterling, 1985). In winter a heated office often falls below 30, because heating warms the outdoor air without adding water. A humidity log shows how many working days the office spends there, and whether a humidifier moved the line.

What is a hygrometer?

A device that reads the humidity of the air in percent. A modern one is a small digital sensor that reads humidity and temperature together. PitCanary is a hygrometer that reads every minute and keeps every reading.

Why is the air so dry in winter?

Because heating does not add water. Outdoor air at 0 °C and 80 percent, warmed to 21, is at about 20 percent: the same water in air that can now hold four times more. Every heated building is dry in winter unless water is added.

Is dry air bad for you?

Under 30 percent, dry eyes, skin and throat are common, and static shocks. Several studies find flu viruses survive longer in dry air. Lowen et al., 2007.

How do I measure humidity in a room?

A hygrometer at seated head height, away from the kitchen, the bathroom, radiators and windows. Check it against a saturated salt solution in a sealed box: it should read 75 percent. Read it through the day, not once; humidity moves with the heating and the people.

What humidity causes mould?

Mould grows where the surface of a wall stays above about 80 percent for weeks, which happens in a room above 60 to 70 percent with cold walls. ISO 13788; WHO 2009. The mould section above explains where it grows first.

What is the dew point?

The temperature at which the water in the air condenses. At 21 °C and 60 percent it is about 13 °C. Any surface colder than that gets wet. PitCanary computes it for every room, every minute.

Is a humidity sensor the same as a hygrometer?

Yes. The sensor is the part inside; the hygrometer is the device. A humidity monitor adds a display or a dashboard; a humidity logger adds memory. PitCanary is all four, with temperature, CO₂ and the dew point next to it.

Can I download my humidity data?

Yes. Every humidity, temperature and dew point reading, by room, day or month, or via the API. It is your data, so it costs nothing.

What humidity should a house or home office be?

Between 30 and 60 percent, the same band as an office. Below 30 the air is dry in winter; above 60 for weeks, mould and dust mites get going on cold walls. Bedrooms and bathrooms rise above 60 for a while every day, which is fine as long as they come back down.

How do you lower the humidity in a room?

Air it out after showers and cooking, dry laundry outside the room, keep cold rooms a little heated, and run a dehumidifier where that is not enough. Then log the humidity for a week to see whether it stays under 60 percent.

What is high humidity?

Indoors, above 60 percent for days or weeks. A shower or a pan on the stove pushes a room higher for an hour, which does no harm. What does harm is a room that stays above 60 to 70 percent, because its cold walls then pass 80 percent and grow mould (ISO 13788).

A humidity data logger for every room.

One PitCanary tells you when the air dries out at noon or turns damp at night, and whether the fix worked. It costs €149 excl. VAT, one time. The dashboard for your first room is free.