Occupancy sensor: which rooms are in use

An occupancy sensor is a sensor that tells whether a room is in use. PitCanary is an indoor climate monitor for offices and home offices that reads presence every minute from movement, voices and the CO₂ people breathe out. You see which rooms were in use, from when to when, never how many and never who.

In short

About a nine-minute read · Updated
What it tells
Whether the room is in use, as a shade from empty to busy.
PitCanary
One of its 15 measurements, read every minute.
How
Radar, sound and CO₂, read together. Someone sitting still usually counts.
How often
A reading every minute, the room's use told per ten minutes.
Over a day
When the room came into use and emptied, and its busiest stretch.
Across rooms
"7 of 10 rooms in use", and when each was free.
Never
A headcount, a name, a recording or an image. Rooms, never people.
Your data
Every reading is yours. Download it or use the API, free.

What does an occupancy sensor measure?

An occupancy sensor measures whether anyone is in a room right now: yes or no. The common kind is a passive infrared (PIR) motion sensor, the kind that switches the corridor lights on as you walk past. Movement is not the same as use. A person reading at a desk hardly moves, and a motion sensor can call that room empty while someone works in it.

Occupancy monitoring asks a wider question: are our rooms used, when, for how long and how intensely? Which meeting room stands empty while people wait for another one? That is a question about rooms over time, and it can be answered without counting a single person.

Three kinds of device answer parts of it. A motion sensor switches lights. A desk occupancy sensor sits under one desk and says whether that desk is taken. A counter at the door counts visitors passing through it. PitCanary is a room occupancy sensor: one device per room, logging use every minute next to the air, light and sound in that room.

How does PitCanary know a room is in use?

PitCanary reads three signals together: movement, voices and CO₂. On the PitCanary in the field today (hardware Rev 1.0), a presence radar inside the tile notices movement, and often the small movement of someone breathing in a chair. The microphone tells quiet from voices on the device itself. The CO₂ sensor shows the air filling with breath. The server reads the three together, so voices or CO₂ that keeps rising count as use even when the radar is quiet. The radar is held against the room's own quiet night, so a twitch in an empty room does not count.

Radar
Movement and stillness. Someone sitting still usually counts.
Sound
Voices, told apart on the device. No audio is recorded or sent.
CO₂
The air filling with breath, from the same sensor as the CO₂ monitor.
Verdict
In use or empty, per ten minutes, with how busy.

None of the three can count. The radar sees that something moves, not how many. Voices are a scene, not a number of speakers. CO₂ rises with breath, and a small room with a few people can rise as fast as a large one with more. That is why PitCanary says how a room is used and never how many were in it. Each of these sensors has its own switch, described with the PitCanary hardware.

What does occupancy monitoring show over a day?

Occupancy monitoring shows when a room came into use, its busiest stretch, the empty hours and when it emptied for the day. An example day in a meeting room: the first meeting runs from nine to half past ten, a short one follows at eleven, and nobody comes in over lunch. From half past one the room is in use again until four, when it empties for the day. Every line below was read on the same minute.

Example: meeting room 2 · one dayEvery line read on the same minute
16:00 · empty
OccupancyIn use 5 h
Voices3 meetings
CO₂Rises with each meeting

Read together, the day explains itself. The room came into use at nine, stood empty over lunch, and its busiest stretch was the afternoon, until it emptied at four. Three signals, one reading of use, and nobody counted.

The room timeline tells that day in words. PitCanary recognises 23 kinds of moment about a room's use. They are part of the 171 kinds of moment and condition PitCanary recognises in a room's day from its readings, each judged for the kind of room it is (counted 8 November 2026). A few of them, and what to do with each:

On the timelineWhat it tells youWhat to do with it
First use of the dayWhen the room came into useHeat and air the room for that time, not earlier
The busiest stretch of the dayWhen the room is at its busiestPlan airing and breaks around it
A long session with no real breakHours of use without a pauseA break, and a window open halfway
Empty over lunchA room that stands empty in the middle of the dayAir it then, or offer it to another team
In use outside active hoursUse before or after the room's usual hoursCheck the hours set for heating, light and alerts
Not used todayA whole day without useA room to rethink, or to heat less

Use explains the other readings, too. The office acoustics page reads talking against an occupied room. The vibration monitoring page tells a door in a busy room from a shock in an empty one. The Room score judges light and sound only while a room is in use.

How do you find meeting rooms that are booked but empty?

You find booked but empty meeting rooms by setting a meeting room occupancy sensor's log next to the booking calendar. A booked room that nobody uses blocks the next team and says nothing about how many rooms you need. PitCanary does not read your booking system. It shows when each room was in use, per ten minutes. The location timeline shows how many rooms were in use at once and when each was free. Lay that next to the calendar and a booked hour in an empty room stands out.

Over weeks, the same log answers the larger question: too few meeting rooms, or too many. If the rooms are never all in use at once, one of them can become a focus room. If they are full every afternoon, you know when the pressure is. The readings in the room then say whether the air held up while it was full.

Can PitCanary be a desk occupancy sensor?

No, PitCanary reads occupancy per room, not per desk. A desk occupancy sensor sits under one desk and says whether that desk is taken, so an office with flexible desks can see which are free. PitCanary is one device per room, and it tells whether the room is in use and how busy it is. Placed on a desk, its vibration sensor also shows typing and knocks on that desk. That is activity, not presence: a person reading quietly reads as idle, and it does not decide whether the room counts as in use.

For a small office, a meeting room, a focus room or a hotel lounge, the room is the unit that matters. One device reads its use next to its air, light and sound. To see which of many flexible desks are free right now, a sensor under each desk is the right tool. For a desk that should signal it is busy, the busy light and Pomodoro timer on the PitCanary shows red or green.

What does PitCanary never record about the people in a room?

PitCanary never records who was in a room or how many: it measures rooms, never people. Across a location it says "7 of 10 rooms in use", never a headcount, never a name. It records no audio and no images. There is no camera, and sound is classified on the device: only the label and the levels leave it, never the sound itself.

Never a headcount
Presence is a shade from empty to busy. Never how many.
Never a name
The radar cannot see who. It sees that something moves.
Never a recording
No audio, no images. Sound leaves the tile as a label and levels.
Never a route
The order in which rooms came into use is never shown as someone walking from one to the next.

One setting works differently, and the hardware page says so. When the Bluetooth scan is on, the device sends the addresses of the Bluetooth devices it hears to the server; off means it does not. The dashboard shows them under Network, as devices near the room, never as people. Whether a room is in use is read from the radar, the sound and the CO₂.

Occupancy sensor questions

What is an occupancy sensor?

A sensor that tells whether a room or a desk is in use. Most see movement, so a person who sits still can read as an empty room. PitCanary reads presence from a radar, the sound and the CO₂ together, so someone working quietly usually still counts, and it never counts how many.

What is the difference between an occupancy sensor and a presence sensor?

Both tell whether someone is there. A presence sensor is usually the more sensitive kind, meant to notice a person sitting still, where a plain motion sensor only notices someone walking. PitCanary uses the word presence for a room in use and reads it from three signals, so stillness usually counts.

Can PitCanary count the people in a room?

No. It tells whether a room is in use and how busy it is, as a shade from empty to busy: never a headcount, never a name. Across a location it says how many rooms were in use, such as 7 of 10, never how many people.

Does it notice someone sitting still?

Usually. The radar reacts to the small movement of someone breathing in a chair, and voices or rising CO₂ cover the rest, so a person working quietly is rarely read as an empty room.

How often does PitCanary read occupancy?

Every minute. The device posts its readings once a minute, and the dashboard tells a room's use per ten minutes, from when it came into use to when it emptied, kept for every day.

Can it show meeting rooms that are booked but not used?

It shows when each room was in use, per ten minutes, and how many rooms were in use at once. PitCanary does not read your booking system, so you set its log next to the calendar, and a booked hour in an empty room stands out.

Does it record audio or images?

No. There is no camera. Sound is classified on the device, and only the label and some numbers leave it; no audio is recorded, stored or sent. The radar and the microphone each have their own switch.

What does the Bluetooth scan send?

When it is on, the device sends the addresses of the Bluetooth devices it hears to the server, and the dashboard shows them under Network, as devices near the room, never as people. Off means it does not. Whether a room is in use is read from the radar, the sound and the CO₂.

How do occupancy sensors work?

Most see movement, with passive infrared or ultrasound, and switch to empty when nothing moves for a while. Some add radar or CO₂. PitCanary reads presence from a radar, the sound level and the CO₂ in the room together, every minute.

What is the best occupancy sensor for an office?

One that notices people who sit still, needs no camera and never counts or names anyone. Look also at whether it logs every room over time, so you can compare a week of meeting rooms. PitCanary does that and measures the room's climate beside it.

Know which rooms are used, without counting anyone.