PitCanary is available from January 2027. Subscribe to the newsletter and we email you the day ordering opens. Subscribe

PitCanary

Indoor air quality monitor for offices

An indoor air quality monitor measures the gases in a room's air: CO₂ from people, VOC from things and NOx from traffic and gas. PitCanary is an indoor air quality monitor for offices, meeting rooms and home offices that reads all three every minute, so you see what is in the air and where it came from. One PitCanary costs €149 excl. VAT, and the dashboard for one device is free.

In short

About a thirteen-minute read · Updated
What it measures
Three gases. CO₂ from people, VOC from things, NOx outside.
CO₂
Used air. Rises with every person, falls with fresh air.
VOC
Vapours from things. Paint, furniture, cleaning. An index.
NOx
Fumes from traffic and gas. Cooking, boilers. An index.
Not measured
Particles, carbon monoxide, radon. Each needs its own sensor.
When it is high
Find the source first. Then ventilate.
PitCanary
Reads all three every minute and shows the air as a colour.
Your data
Every reading is yours. Download it or use the API, free.

What is indoor air quality?

Indoor air quality is how clean the air inside a building is, and in an office it comes down to three gases from three sources. People breathe out CO₂. Things give off VOC: volatile organic compounds, the vapours from paint, glue, new furniture, cleaning products, printers and perfume. The street and the kitchen bring NOx: nitrogen oxides from traffic, gas hobs and boilers.

Each has its own source, its own pattern and its own fix. A room can be fine on one and bad on the other two. The CO₂ monitor page covers the first gas in depth.

  • PeopleCO₂BreathMeetingsBookings

    Rises with every person in the room. Falls with fresh air. Follows the meeting calendar.

  • ThingsVOCCleaningPaintFurniturePrinter

    Highest after cleaning and after a fit-out. Often highest when the room is empty.

  • Outside and gasNOxTrafficGas hobWindow

    Comes in with the window during rush hour. Peaks at cooking time.

What you notice

Smell
VOC, the first minutes in a room. Freshly cleaned or newly fitted. The nose gets used to it. The sensor does not.
Dry eyes and throat
Hours in a room with high VOC. The classic new-office complaint.
Headache
CO₂ and VOC together. Heavy, late in the day.
Coughing
NOx at high levels. Gas cooking in a small kitchen, or a window on a busy road.

You smell the air for the first minute. PitCanary reads it every minute, and tells you which of the three it is.

Sources: WHO Air Quality Guidelines, 2021 (NO₂); Umweltbundesamt, TVOC guide values; EN 16798-1.

What is a normal VOC level in an office?

On a VOC index, 100 is the room's own normal, and PitCanary reads up to 250 as green in an office, its own band. CO₂ is counted in ppm, but VOC and NOx are not. There are hundreds of different VOCs and a small sensor cannot name them. So it reports an index: how much more or less there is than the room's own normal. Above 250 is a lot more, and 50 is cleaner than usual. NOx works the other way round: 1 is clean air, and the index climbs when nitrogen oxides arrive.

That is enough to act on. The scale below cuts the index into three bands. Green is normal for this room. Orange means something is in the air that was not there before. Red means a lot of it: ventilate now and find out what changed.

Green

Normal for this room.

Orange

Something new in the air. Open a window, find the source.

Red

Ventilate now.

The air quality bands follow the Air part of the Room score. PitCanary's band for CO₂ sits beside EN 16798-1 and is explained on the CO₂ page. The VOC bands are set against the room's own normal; the NOx index is indicative. The green edge, 250, is PitCanary's band, not a standard's.

What does indoor air quality look like over a day?

Over one day, the three gases peak at different times for different reasons, as in this meeting room next to a main road. At seven the cleaners come through and the VOC line jumps while the room is still empty. At eight someone opens the window and the NOx line rises with the rush hour outside. At ten the meeting starts and CO₂ climbs the way it does on every meeting day.

Three peaks, three causes, one room. A single number for "air quality" would have shown one bad morning and told you nothing about why.

Meeting room 2 · TuesdayAn example day, drawn for illustration. CO₂ in ppm on the left, VOC and NOx index on the right
  1. 1Cleaning
  2. 2Window opened, rush hour
  3. 3Meeting starts
An example day. CO₂, VOC and NOx in a meeting room over 24 hours. VOC jumps at 07:00 during cleaning, NOx rises at 08:00 when a window opens in rush hour, CO₂ climbs from 10:00 during a meeting.

Three readings on the same minute is what makes the cause visible. That is why PitCanary never reads one gas alone.

How long does it take for indoor air to clear?

A smell halves in about 8 minutes with the windows wide open and in about 2 hours 20 in a closed room, because it leaves at the speed the air is replaced. CO₂ comes from people, so it keeps rising while they are in the room. VOC and NOx mostly come from a source that stops: the cleaner leaves, the window closes, the printer finishes. From that moment the line falls, and how fast depends only on how often the air in the room is replaced.

2 h 20to half, closed room, about 0.3 air changes an hour
40 minwindow on the latch, about 1 air change an hour
14 minmechanical ventilation, about 3 an hour
8 minwindows wide open, about 5 an hour

Half-life is ln 2 divided by the air changes an hour. The air change figures are rules of thumb, the same as in the CO₂ calculator.

How do you improve indoor air quality in an office?

You improve indoor air quality in an office by finding the source first and then ventilating at the right moment. Fresh air fixes all three gases. But with VOC and NOx the first question is where it came from, because the fix is often not a window.

Start with the cleaners. VOC peaks right after they leave, and ten minutes with the windows wide open before people arrive clears more than half of it. New carpet, paint and furniture do the same for weeks rather than an hour. They give off most of their VOC early, so ventilate hard in that period and the line settles by itself.

NOx asks for timing instead. On a busy road it comes in with the rush hour, so the window that clears the CO₂ at eight lets the traffic in. Open wide at ten and the dashboard shows the difference. Indoors the biggest NOx source is a gas hob: cook with the hood on and the kitchen door shut, and the office stays out of it.

If the VOC line is high every morning and the NOx line every rush hour, the fix is a schedule, not a device. The timeline is what shows you the schedule.

What does an air quality sensor measure?

An air quality sensor measures one gas or group of gases, and an indoor air quality monitor puts several of them in one box. A CO₂ sensor counts carbon dioxide with infrared light. A VOC sensor is a heated metal-oxide surface that changes its resistance when vapours land on it. It reports how much more or less there is, not which vapour. A NOx sensor works the same way for nitrogen oxides.

Check three things before you buy an indoor air quality monitor. Does it have a real CO₂ sensor, or does it calculate "eCO₂" from the VOC reading? Does it report VOC as a plain index, or does it claim ppb to three decimals from a sensor that cannot deliver that? Does it keep the readings, or only show the number now?

And be honest about what a box this size cannot do. Fine particles (PM2.5) need a separate particle sensor. Carbon monoxide needs its own alarm, and radon needs a radon meter. A monitor that claims all of them in one small box without naming the sensors is guessing on some of them.

PitCanary reads CO₂, VOC and NOx with their own sensors, and does not claim particles, carbon monoxide or radon.

How do you check the indoor air quality in an office?

You check the indoor air quality in an office by logging CO₂, VOC and NOx in each room for at least a normal working week. A one-off test shows one moment; a week shows the cleaners, the rush hour and the meetings. PitCanary reads the three gases every minute and never one alone. Temperature, humidity, light, sound and presence are read on the same minute.

So when the VOC line jumps in an empty room, you know it was the cleaners and not the people. When NOx rises with an open window, you know it was the street.

Meeting room 2 · one morningEvery line read on the same minute
07:00 · cleaning
VOC340 peak
OccupancyEmpty until 08:30
WindowOpen 10 min
Temperature19.8 °C low

Read together, the morning explains itself. The room was empty, the VOC line jumped at seven, and ten minutes of open window at half past brought it back.

Can an air quality monitor log every reading?

PitCanary logs every CO₂, VOC and NOx reading, one a minute, so it works as an air quality data logger as well as a monitor. Most air quality meters show the number now and forget it a minute later. PitCanary keeps it, with the temperature, humidity, light and sound next to it, in a log for the room. Months later you can still see which days went bad, for how long and why.

That log is yours, not ours, and getting it out costs nothing. There is no export fee and no paid tier for your own history. The PitCanary API serves the same readings as JSON, and Home Assistant reads them over MQTT.

Meeting room 144,640 readings this month, one per minute
TimeCO₂ ppmVOC indexNOx indexTemp °CHumidity %Occupancy
15:58852262322.348Empty
15:59851266322.348Empty
16:00850270422.348Empty
  • On the timelineEvery hour of every day, with what changed and why.
  • As a downloadBy room, day or month, as CSV.
  • Through the APIInto your building system, BI tool or app.

So you read a day the way you read a log. Not a number at this minute, but what changed and why.

Insights / HQ / Room 5A reading every minute
Timeline · TodayOne morning: the air went heavy, the advice came, the window opened
  1. 09:58: advice followed in 12 minutes. Advice at 09:58. Outside air came in at 10:10; CO₂ fell from 914 to 737 ppm in 12 minutes. The advice worked within a quarter of an hour.
  2. 07:40 to 08:00: the air got less fresh for 20 minutes. The air quality index rose from 140 to 376 between 07:40 and 08:00, while voices were in the room. It eased by itself once the room settled.
  3. 07:20 to 10:20: CO₂ to 914 ppm, then aired. CO₂ rose from 456 ppm at 07:20 to 914 at 09:50, fastest while voices were in the room, and fell to 737 after the airing. Stayed under 1,000 ppm. The airing came about half an hour before the room would have turned stale.

Which gas rises in which room?

CO₂ rises in a full meeting room, VOC after cleaning or a fit-out, and NOx next to a gas hob or a busy road. Most air quality meters have one number for every room. But the printer room, the kitchen and the meeting room by the road have three different problems. This table is the reference: the room, what rises, where it comes from and what the guidance says.

Room or situationWhat risesWhere fromWhat the guidance says
Meeting room, door shutCO₂People800 ppm above outdoor, EN 16798-1
Open office, first weeks after a fit-outVOCCarpet, paint, glue, new desksTVOC under 300 µg/m³ is the target. Under 1,000 is acceptable. Above 3,000 not for daily use (Umweltbundesamt)
Any room, the hour after cleaningVOCCleaning productsAs above. Peaks are short if the room is aired
Printer and copy roomVOCToner, paper, the machinesThe TVOC values above apply. Keep the door shut and the room ventilated
Kitchen with a gas hobNOxGas burningNO₂ 25 µg/m³ as a daily average (WHO 2021). A hob without a hood can push short peaks far above it
Room on a busy roadNOxTraffic through the windowNO₂ 10 µg/m³ as a yearly average (WHO 2021). Open the window outside rush hour

Sources: EN 16798-1:2019; Umweltbundesamt, TVOC guide values; WHO Air Quality Guidelines, 2021. PitCanary reports VOC and NOx as an index, not in µg/m³. The table explains the guidance, not a direct reading.

PitCanary knows fifteen room types and reads each against what that room should expect. Set the room type once. The light, the timeline and the Room score do the rest. The indoor climate page puts air quality next to temperature, humidity, light and sound.

Questions about indoor air quality monitors

What does an indoor air quality monitor measure?

Usually CO₂, VOC and sometimes NOx, next to temperature and humidity. Some add fine particles with a separate sensor. PitCanary measures CO₂, VOC and NOx, plus temperature, humidity, light, sound and presence.

How do I check the indoor air quality in an office?

Log CO₂, VOC and NOx in each room for a normal working week. A one-off test shows one moment; a week shows the cleaners, the rush hour and the meetings. PitCanary reads all three every minute and keeps every reading.

What is VOC in indoor air?

Volatile organic compounds: vapours from paint, glue, new furniture, carpet, cleaning products, printers, perfume and cooking. There are hundreds. A VOC sensor reports how much there is in total, not which ones.

What is a normal VOC level in an office?

On a PitCanary the VOC index is read against the room's own normal, 100. Up to 250 is green, PitCanary's band for an office. As a concentration, the German Umweltbundesamt calls under 300 µg/m³ the target and under 1,000 acceptable.

What is NOx and where does it come from indoors?

Nitrogen oxides, mainly NO₂. Indoors they come from gas hobs, gas boilers and traffic through an open window. The WHO guideline is 25 µg/m³ as a daily average.

Does an air quality sensor measure fine particles?

Only if it has a particle sensor, which is a separate part with its own air path. PitCanary does not measure particles. A device that claims PM2.5 without naming a particle sensor is guessing.

What is eCO₂, and is it the same as CO₂?

No. eCO₂ is an estimate of CO₂ calculated from a VOC sensor. It follows perfume and cleaning as much as people. A real CO₂ sensor uses infrared light. PitCanary has one.

How do I improve indoor air quality in an office?

Find the source first, then ventilate at the right moment. Air out after cleaning, ventilate hard in the weeks after a fit-out, open windows outside rush hour on a busy road, and run the hood over a gas hob. Then measure for a week and see which line still rises.

Is high VOC dangerous?

At office levels it is a comfort and health problem, not an emergency: smell, dry eyes, headache. Very high levels over long periods are a health concern, which is why the guidance sets limits.

Can I download the air quality data?

Yes. Every CO₂, VOC and NOx reading, by room, day or month, or via the API. It is your data, so it costs nothing.

How do you test indoor air quality?

Measure CO₂, VOC and NOx in the room for at least a normal week. A one-off test or a lab sample shows one moment; a week of readings shows when the air goes bad and why. PitCanary reads all three every minute in every room.

How do you improve indoor air quality in a home office?

Air the room often. A home office is small and often closed, so CO₂ from one person passes 1,000 ppm within a few hours. Open a window a little or air it every hour, keep printers and new furniture out of the room for a while, and measure to see what helps.

An indoor air quality monitor that names the cause.

CO₂, VOC and NOx on one timeline, so you fix the cause instead of the complaint. One PitCanary costs €149 excl. VAT, one time. The dashboard for your first room is free.