In short
About a sixteen-minute read · Updated- What it is
- A temperature sensor in every room, logged every minute, with humidity.
- Office
- 20 to 24 °C in winter, 23 to 26 °C in summer. EN 16798-1.
- The law
- UK: 16 minimum, HSE. DE: 20 minimum, ASR A3.5. NL: no number.
- Hotel room
- 18 to 24 °C, 17 to 22 °C at night. PitCanary's band.
- Bedroom
- 17 to 22 °C. PitCanary's band for sleep.
- Wine cellar
- 10 to 15 °C, steady. A daily swing under 2 °C matters more than the number.
- A data logger
- Keeps every reading. A thermometer keeps none.
- PitCanary
- Logs every minute and lets you share the log with anyone.
- Your data
- Download it, use the API, or give your landlord a login.
Years of arguing about the heat. Then a logger, and a line.
In twenty years of offices I have sat in rooms that were never right. One building had small rooms along the outside wall. In winter people worked in their coats. On a summer morning the same rooms were at 30 degrees before anyone had opened a laptop. Every year the same discussion with the landlord: too hot, too cold, the heating is late, the sun is early.
In the end the landlord installed temperature loggers so both sides could see what the rooms did. That helped, for a while. But the loggers were awkward boxes, nobody had calibrated them, and they only knew the temperature. Not whether the sun was on the window, whether the room was full, or what it was outside.
A PitCanary shows it in the first week: the ramp at seven when the heating starts, the spike at three when the sun comes round, and one login for the tenant and one for the landlord. The same line on both screens ends most of the discussion.
What is a temperature monitoring system?
A temperature monitoring system is a set of temperature sensors, one per room, that send every reading to one dashboard where it is logged, compared with the room's band and turned into alerts. It replaces the thermostat display and the thermometer on the wall. The thermostat shows what it is set to, not what the room is. The thermometer shows one spot at one moment, usually next to the radiator or the window. And the complaints come at four, about something that happened at three.
A temperature sensor on its own fixes the number. A log fixes the time. With both you see three things: how far the room is from where it should be, how long it stays there, and what moved it. The heating that starts an hour late. The sun that hits the west wall at three. The meeting that adds four people and two degrees. The night the building never cools.
A remote temperature monitoring system does this without anyone in the room: the readings arrive over Wi-Fi, and you check every room from one screen. PitCanary is a wireless temperature monitoring system of that kind: one device per room, the data over Wi-Fi, power from a USB cable, and no laptop or USB stick in between.
What you notice
- Cold hands, cold feet
- Below about 20 °C for seated work. Coats on indoors, hands on the mug. Typing gets slower.
- Sleepy and slow
- Above about 25 °C. The afternoon drags, errors go up, the room smells of warm carpet.
- Dry air
- Warm rooms in winter are dry rooms. Dry eyes, a scratchy throat, a voice that gives out by five.
- Draughts and cold walls
- The middle of the room is fine and the desk by the window is not. One reading on the wall never shows it.
You feel 26 degrees by half past three. PitCanary logged it at half past one, and shows which rooms and which afternoons.
Sources: EN 16798-1:2019; ASR A3.5; HSE Workplace (Health, Safety and Welfare) Regulations 1992; Seppänen, Fisk and Lei, 2006, on productivity and temperature.
What temperature should an office be?
An office for seated work should be 20 to 24 °C in winter and 23 to 26 °C in summer, according to EN 16798-1 Category II. Below about 20 °C people reach for their coats, and above about 25 °C the afternoon drags. The right temperature is a band, not a number, and the band depends on the room: twenty-three degrees is a good office and a bad wine cellar.
PitCanary knows which room type it is in and cuts the scale around that room's band. The base of the PitCanary breathes the colour of the band, so everyone sees whether the room is where it should be, without reading a number. Orange is a nudge. Red means the room has been out of its band for a while.
Too cold. Check the heating and the window.
Right for this room.
Too warm. Shade the window, open it early.
Act now.
Office bands from EN 16798-1 Category II. Other room types from the table below. Each market reads the band against its own rule, such as ASR A3.5 or the Arbo guidance; the colours stay, the edges move.
How do you measure office temperature?
You measure office temperature with a logger at seated head height, away from radiators, sun and outside walls, for at least a normal working week. A reading every minute shows when a room leaves its band, for how long and what moved it, which a thermometer read once a day never shows. Take one Tuesday in a corner office with a west window. Overnight the room drifts down to 17. At seven the heating starts and the line climbs for an hour before anyone is in. By ten it is 22 and steady. At two the sun reaches the window and the line climbs again, to 27 by half past three, with the heating still on. Everyone leaves at six. The room is still 25 at nine in the evening.
- 1Heating on
- 2Sun on the window
- 3Everyone left
A thermometer would have said 22 at ten and 27 at three, to whoever looked. The log says the room spends two hours a day above its band, every sunny day, and that the heating runs while the sun does the work.
What is the minimum office temperature, and is there a maximum?
In the UK an office should be at least 16 °C, or 13 °C for physical work, under the HSE's Approved Code of Practice to the Workplace (Health, Safety and Welfare) Regulations 1992, and there is no legal maximum. Germany sets 20 °C as the minimum for seated light work in ASR A3.5, and the Dutch Arbobesluit sets no number at all. Most workplace rules give a minimum and a point where the employer has to act, and few give a maximum. None of them tells you what your room does, which is why the discussion with the landlord never ends.
How do you keep an office at the right temperature?
Start the heating earlier, stop it earlier and shade west windows before the sun arrives, because most office temperature problems are timing problems. Timing is what a log shows. The heating in most offices starts when the first people arrive and stops when the last one leaves. That sounds logical, but a building is slow. A cold room needs time to reach 20 °C, often more than people expect, so everybody spends the first part of the morning in their coat. The usual answer is to turn the thermostat up, which does not make the room warm any sooner; it only makes it too warm later.
Then the afternoon. A west-facing office gets the sun from about two o'clock, and the sun is a heater that nobody switches. If the heating is still running at that moment, the two add up, and by half past three the room is at 27. The fix is the same move at both ends of the day: start the heating earlier, and stop it earlier. From six in the morning, the room is at 20 by eight. Off at two, the sun takes over and the room stays in its band. Same thermostat setting, two hours less heating, a very different day.
Two smaller moves help on top of that. Shade before the sun arrives: blinds down at one keep a west office under 26 at three, blinds down at three do not. And after a hot night, open the windows early in the morning, from seven to nine, to let the stored heat out; open at noon they let the heat in. All of it starts with one sensor per room, because the corridor can be 22 while the corner office is 27, and only a log per room shows which rooms need the change.
If a room is always orange whatever you do, the building is the problem, not the people. That is a finding, not a failure, and a year of readings is what makes the case to the landlord.
What is a temperature data logger?
A temperature data logger is a temperature sensor with a memory: it reads the temperature on a fixed interval and keeps every reading. A thermometer is a sensor without a memory, so it shows one moment and forgets it. Most temperature loggers are small USB boxes that read every few minutes. You plug one in, set the interval, leave it in the room for a week and plug it into a laptop to read the file.
Three things to check before you buy one. The accuracy, as the datasheet states it; a cheap logger can be out by the whole argument with the landlord. The interval; every minute shows the sun at three, every fifteen minutes blurs it. And how you get the data out; a file on a USB stick is not something two people look at together.
How do you measure office temperature?
Measure office temperature at head height when seated, away from radiators, direct sun and outside walls, and log it for at least a normal working week. A logger on the wrong wall logs the wall, not the room. One reading at ten in the morning says nothing about the afternoon, so compare the log with the band for the room type, hour by hour. Put one sensor in each room people complain about, and one in a room nobody complains about, so you have something to compare with.
PitCanary is a temperature data logger that posts every minute, needs no laptop to read, and reads humidity and CO₂ next to it.
How does PitCanary monitor temperature?
PitCanary reads the room's temperature every minute with a digital temperature and humidity sensor, and posts every reading to the dashboard. The temperature is never measured alone. Humidity, CO₂, light and occupancy are read on the same minute, out of 15 measurements in all. So when a room runs hot, you see why: the sun on the window, a full room, a heating schedule that does not match the day.
That is the difference with a stand-alone temperature sensor or a USB data logger. Both give you a number; PitCanary gives you the number with its cause, and an alert when a room stays out of its band.
Read together, the afternoon explains itself. The light jumped at two, the room was in use, and the line climbed with the sun.
- Temperature sensor
- A digital temperature and humidity sensor, read every minute.
- Interval
- A reading every minute, posted every minute.
- Context
- Humidity, CO₂, light and occupancy on the same minute.
- Logging
- Every reading kept, export by room, day or month.
What temperature should each room be?
Each room type has its own temperature band, and PitCanary reads every room against the band of its type. An office in summer, a hotel room at night and a wine cellar all year want very different things, and two of them care more about the daily swing than the number. This table is the reference: the room, the temperature it should be, and what to watch.
| Room | Temperature | What to watch | Standard or guidance |
|---|---|---|---|
| Office, seated work | 20 to 24 °C | Under 20 by nine o'clock means the heating starts too late. Above 26 in the afternoon means the sun, not the weather | 20 to 24 °C in winter, 23 to 26 °C in summer (EN 16798-1, Category II) |
| Meeting room | 20 to 24 °C | A full room warms itself; a log shows how fast | 20 to 24 °C (EN 16798-1, Category II) |
| Hotel room | 18 to 24 °C | A guest room should cool at night; PitCanary reads the night against its own band | PitCanary's band |
| Hotel lounge | 20 to 25 °C | Guests sit still here; the seat by the door or the window feels a draught before the thermostat does | PitCanary's band |
| Bedroom | 17 to 22 °C | A warm room at night is the complaint at breakfast | PitCanary's band |
| Server room | 18 to 27 °C, daily swing up to 5 °C | Measured where the air goes in: hot spots behind the rack, not the room average | 18 to 27 °C at the server inlet (ASHRAE TC 9.9) |
| Wine cellar | 10 to 15 °C, daily swing up to 2 °C | Steady matters more than the number; repeated swings push the cork | PitCanary's band; trade consensus, no formal standard |
| Archive | 10 to 20 °C, daily swing up to 4 °C | The swing matters more than the number; paper and wood move with it | Daily swing up to 4 °C (ISO 11799) |
The band column is the one PitCanary reads that room type against, from its room type registry. Sources for the guidance column: EN 16798-1:2019, Category II (offices, meeting rooms); ASHRAE TC 9.9 (server rooms); ISO 11799 (the archive's daily swing); the wine storage trade consensus, which is not a formal standard (wine cellars). The hotel room, hotel lounge and bedroom bands are PitCanary's own.
PitCanary knows fifteen room types, the wine cellar among them, and judges each against its own band. In a wine cellar PitCanary flags a daily swing above 2 °C, because steady matters more than the number. Set the room type once. The light, the timeline and the Room score do the rest. Temperature is one of five parts of a good indoor climate, next to air, humidity, light and sound.
Questions about temperature monitoring and data loggers
What temperature should an office be?
20 to 24 °C in winter and 23 to 26 °C in summer for seated work, according to EN 16798-1 Category II. Above 25 °C performance falls about 2 percent a degree (Seppänen, Fisk and Lei, 2006). PitCanary reads an office against 20 to 24 °C.
What is the minimum office temperature in the UK?
At least 16 °C, or 13 °C for physical work, under the HSE's Approved Code of Practice to the Workplace (Health, Safety and Welfare) Regulations 1992, and there is no legal maximum. Germany sets 20 °C for seated light work in ASR A3.5 and tells employers to act above 26 °C. The Netherlands sets no number. None of them tells you what your room does; a log does.
How do I measure office temperature?
Put a temperature data logger at head height when seated, away from radiators, direct sun and outside walls, and log at least a normal working week. One reading at ten in the morning says nothing about three in the afternoon. Compare the log with the band for the room type, hour by hour.
What is a temperature monitoring system?
A set of temperature sensors, one per room, that send every reading to one dashboard, where it is logged, compared with the room's band and turned into alerts. PitCanary is one: a device per room posts the temperature every minute over Wi-Fi, with humidity, CO₂ and light beside it.
What is a temperature data logger?
A sensor with a memory. It reads the temperature on a fixed interval and stores every reading, so you see the whole day instead of one moment. PitCanary logs every minute and posts it to a dashboard, so nobody has to plug anything in.
How accurate should a temperature sensor be?
Accurate enough that two loggers side by side for a day agree, and check the stated accuracy before you buy. A cheap logger can be out by the whole difference between "too hot" and "fine".
Can I share the temperature log with my landlord?
Yes. Invite your landlord as a viewer and they see the locations you choose, with every reading. Both sides look at the same line.
Can I download or export the temperature data?
Yes. Every reading, by room, day or month, as a CSV, or via the API. It is your data, so it costs nothing.
What temperature is too hot for an office?
The UK sets no legal maximum. Germany tells employers to act above 26 °C (ASR A3.5), and most people in an office feel too warm above about 25 °C. A temperature log shows how many working hours a room spends there.